Vivo Cryowrap Cooler Unit

•    Insulated flask for ice/cold water
•    Gravity fed cryotherapy system delivering cold water and support to joints
•    Integrates with compression wraps to reduce swelling around ankles and knees
•    Provides cold and compression therapy to swollen knee and ankle joints
•    Used as part of the PRICE regime. Protect, Rest, Ice, Compression, Elevation
•    The method is widely used in hospitals post-surgery
•    Available to buy with or without knee or ankle sleeves

The product consists of cooler, tube and sleeve (sold separately, or as a combination). The cooler is made of urethane foam and high-density polyethylene plastic, the sleeve is made of polyurethane coated nylon.

The Vivo-Cryowrap Cooler Unit is intended to be used for cold therapy on specific parts of human body surface.

Instructions for use:

1.Prepare cooler: Connect the blue tube to the cooler. Add water to line inside the cooler, then add ice. For 6 to 8 hour treatment, add ice to top of cooler. Lay the insulation disk on top of ice. Attach cooler lid snugly. Allow 5 minutes with occasional shaking to chill water.
 2.Apply the empty sleeve: Use a medical isolation pad between your desired area and the sleeve, Position sleeve on the joint with quick-disconnect pointing down. Thread straps through white rings and secure snugly.
 3.Fill sleeve: Connect blue tube to sleeve. Open air vent on cooler lid and raise cooler no more than 15.7 inches(40cm) above the sleeve (if the cooler is raised more than 15.7 inches(40cm), the sleeve will increase in volume and weight.) Hold raised cooler for about 30 seconds while sleeve fills. Close air vent on cooler lid. the cooler can now be disconnected from sleeve by pressing the tab on the quick-disconnect while cooler is raised.
 4.Rechill water: At first, rechill the water in the sleeve after 15 or 30 minutes, then once an hour or as needed. Reconnect the blue tube to sleeve. lower the cooler below sleeve, and the warmed water will drain from the sleeve into the cooler. Allow a minute or two for the water to mix with the ice and rechill, then raise the cooler and repeat the filling process.